LC-E

Control gears up to 50W. IP20
  • Product conformity
  • International regulations
  • SELV control gear
  • Device protected against over temperature
  • SELV
  • ORC < 4%
Contact with us
Ref. No.Output power rangeWOutput currentsmAOutput voltage rangeVdcPower factorλSystem efficiencyƞ (%)Max. temp. at tc pointtc (ºC)Operating temp.ta (ºC)
LC 150/350-E991817123…5035066…1430,989075-20…+50
LC 150/500-E991817223…5050046…1000,989075-20…+50
LC 150/700-E991817324…5070034…720,988975-20…+50
LC 148/1050-E991817423…48105022…460,988775-20…+50
LC 142/1400-E991817518…42140013…300,988675-20…+50
LC 150/350-E-FAN991821123…5035066…1430,989075-20…+50
LC 150/500-E-FAN991821223…5050046…1000,989075-20…+50
LC 150/700-E-FAN991821324…5070034…720,988975-20…+50
LC 148/1050-E-FAN991821423…48105022…460,988775-20…+50
LC 142/1400-E-FAN991821518…42140013…300,988675-20…+50

IP20 equipment.

Driver for built-in use. Class I.

High power factor.

Thermal protection.

Overload protection.

Short circuit protection.

Protection against no load operation.

Withstands 2 hours at 350V (AC).

Permitted input voltage AC/DC 198-264V.

Rapid connector with fixing spring.

Conductor size 0,5-1,5 mm2.

Drivers connection in series.

Nominal lifetime at max. tc allowed: 50.000h.

Output ripple current (ORC) <4%.

Low Total Harmonic Distortion (THD) <10%.