LC-A-UN

Control gears up to 25W. Universal voltage 110-277V. IP20
  • Product conformity
  • International regulations
  • Class II indication
  • Independent auxiliary device
  • SELV control gear
  • SELV
Contact with us
Ref. No.Output power rangeWOutput currentsmAOutput voltage rangeVdcPower factorλ110V230VSystem efficiencyƞ (%)Max. temp. at tc pointtc (ºC)Operating temp.ta (ºC)
LC 125/350-A-UN99182618…2535023…720,990,948580-20…+50
LC 125/500-A-UN99182628…2550016…500,990,948575-20…+50
LC 125/700-A-UN99182638,5…2570012…360,990,948580-20…+50

IP20 equipment.

Class II electrical protection.

Indoor use.

Equipped with terminal cover and cable clamps.

Clamping screws on primary and secondary circuits for cables with diameter: 3 mm to 8 mm.

Max. terminal section area 2,5 mm². (secondary circuit).

Suitable for installation on wooden surfaces.

High power factor.

Thermal protection.

Overload protection.

Short circuit protection 

Protection against no load operation.

Permitted input voltage AC/DC: 99-305V.

Nominal lifetime at max. tc allowed: 50.000h.

Back

Subscribe to our newsletter

CAPTCHA
This question is for testing whether or not you are a human visitor and to prevent automated spam submissions.
13 + 0 =
Top