Ref. No. | Output power rangeW | Output currentsmA | Output voltage rangeVdc | Power factorλ | System efficiencyƞ (%) | Max. temp. at tc pointtc (ºC) | Operating temp.ta (ºC) | |
---|---|---|---|---|---|---|---|---|
LC 150/350-D | 9918103 | 23…50 | 350 | 66…143 | 0,98 | 90 | 75 | -20…+55 |
LC 150/500-D | 9918105 | 23…50 | 500 | 46…100 | 0,98 | 90 | 75 | -20…+55 |
LC 150/600-D | 9911605 | 21…43 | 600 | 34…72 | 0,98 | 89 | 75 | -20…+55 |
LC 150/650-D | 9911606 | 22…47 | 650 | 34…72 | 0,98 | 89 | 75 | -20…+55 |
LC 142/700-D | 9918102 | 24…42 | 700 | 34…60 | 0,98 | 89 | 75 | -20…+55 |
LC 150/700-D | 9918107 | 24…50 | 700 | 34…72 | 0,98 | 89 | 75 | -20…+55 |
LC 148/1050-D | 9918109 | 23…48 | 1050 | 22…46 | 0,98 | 87 | 75 | -20…+50 |
LC 190/600-D | 9911607 | 35…77 | 600 | 58…129 | 0,98 | 91 | 75 | -20…+50 |
LC 190/650-D | 9911608 | 38…84 | 650 | 58…129 | 0,98 | 91 | 75 | -20…+50 |
LC 190/700-D | 9918117 | 40…90 | 700 | 58…129 | 0,98 | 91 | 75 | -20…+50 |
IP20 equipment.
Driver for built-in use. Class I.
High power factor.
Overload protection.
Short circuit protection.
Protection against no load operation.
Withstands 2 hours at 350V (AC).
Permitted input voltage AC/DC: 198-264V.
Rapid connector with fixing spring.
Conductor size 0,5-1,5 mm2.
Nominal lifetime at max. tc allowed: 50.000h.
Output ripple current (ORC) <2%.
Low Total Harmonic Distortion (THD) <10%.